Slow the Flow

Outfall and tide-locking assessment

Test whether inflow can be stored while a one-way outfall is restricted by downstream levels.

Assessment record

Replace all example numbers and identify their survey or event source. Use metres on one vertical datum. Enter surveyed water levels and inundated plan areas. Supply event times in minutes from a recorded start. Flow entries apply from each row to the next. The final row sets the end time. Supply downstream levels on the same datum and the available discharge capacity of the open outlet.

Survey and event inputs

Results and plots

Free screening tool. The assessor retains responsibility for the survey, assumptions and interpretation.

Method and sources

Surface area varies linearly between surveyed levels. Integrating area gives stored volume. At each interval, change in volume equals (inflow − released flow) × elapsed time. Discharge is limited by available water. At first spill, water above the crest storage is recorded as excess and the level is capped at the crest. Actual flood levels after spill require an overflow rating. Downstream levels are interpolated linearly. The one-way outlet closes when the internal level is at or below the larger of the sill and downstream level plus opening head. At five-second or shorter steps the supplied open-outlet capacity is limited to the water available above that level. This simplified flap rule assumes no reverse flow or leakage. Enter measured or independently rated capacity and test a range.