Pipe flow and condition calculator
Compare a clear pipe with the surveyed reach. Bring its internal bore, invert gradient, CCTV or inspection record, sediment depth and any evidence of downstream backing-up. For a connection, bring the simultaneous existing and proposed peak inflows.
Reach and gradient
Material and condition
Connection and event evidence
Use coincident flows for the same event. Enter zero only where supported. A local obstruction, displaced joint, collapse or roots needs a separate restriction check. The sediment calculation represents a level bed along the reach and one effective roughness around the wetted perimeter.
Flow comparison
Free professional screening tool. The assessor retains responsibility for the evidence, assumptions, interpretation and design.
Method and sources
The Wallingford Procedure, Volume 1, chapter 8 and Table 8.1 – pipe resistance and roughness. The clean benchmarks assume precast ring-jointed concrete, sleeve-jointed clay or ring-jointed uPVC. The slimed benchmarks come from tests on 225 mm combined sewers slimed to about half depth. For surface-water investigations these are sensitivity scenarios. Choose a surveyed value where evidence supports one.
Water UK, Sewerage Sector Guidance Appendix C v2.3, Part C – surface-water sewer adoption design in England. The 0.6 mm option is a design assumption.
C. F. Colebrook (1939), Turbulent flow in pipes, Journal of the Institution of Civil Engineers 11, 133–156. Combine Colebrook–White with Darcy–Weisbach using the Darcy friction factor. With hydraulic diameter Dₕ = 4A/P and u = √(2gDₕS), V = −2u log₁₀[kₛ/(3.7Dₕ) + 2.51ν/(Dₕu)]. Q = AV. SI units are used internally. Part-full and sediment cases use the hydraulic-diameter approximation.
IAPWS, viscosity of ordinary water. Temperature presets use rounded freshwater kinematic viscosities at atmospheric pressure.